(Displays on the 5th occurrence of "HFL" message with 24 hours). One sensor has detected 118° F at heater. Note:  The control system brand name is usually different from the hot tub brand name. OH = Temp exceeds 118° F Apr 3, 2007 98. Do not enter the spa. dr = Inadequate water detected in heater. Cleaning the top and underside of the cover with a solution of mild soap and water is the safest method. Here are the common spa topside panel messages that you will encounter with your spa panel. High Limit Fault - - - , - - - ‘Watchdog’ - 48C reached, electronic fault, shuts system down. C. ChrisL Well-known member. One sensor has detected 110ºF. SN = Non functional high temperature sensor. ", SpaDepot on Facebook (opens in a new tab), SpaDepot on Instagram (opens in a new tab), SpaDepot on Pinterest (opens in a new tab), SpaDepot Hot Tub Care Blog (opens in a new tab), Hot Tub Topside Keypad Error Codes & Messages. We bought a used hot tub. I have a 5-6 year old spa/hot tub, it was fitted by the OEM with some version of the Balboa 2000LE controller/heater system, and dual 2 speed pumps. You should see 220 volts on your volt meter - note that measuring from each wire to ground will not give an accurate reading). CL = Current Time of Day C. ChrisL Well-known member. Causing the heater to cut off. It ran pretty well for a week or 10 days but stayed foamy, We emptied it, cleaned it and refilled it. My 220 Volt Spa No Longer Gets Hot; When calling for heat, is the heat indicator light/icon on on the topside control? If your spa is equipped with a circulating pump, there is a screen-like fitting in your hot tub that bubbles and/or hot water comes out of. We can help you learn if it is indeed an error code, or if it's just a system status message. Fldu = Filter Cycle Duration Most Balboa hot tub control systems have three operating modes: Standard, Economy and Sleep. Flo = Improper flow or pressure switch malfunction Flo = Improper flow or pressure switch malfunction Cool = Water temp 20° below set point ICE = Potential freeze condition has been detected Refer to NEC (National Electrical Code), 2005 Edition, Article ... All material copyright of Balboa Water Group. SN code on Balboa control. Yes, It Is: Measure the voltage across both hot wires coming from the house. View and download marquis 660 owners manual online. FLO = Pressure Switch Alarm The panel will also display diag-nostic messages that enable the service technician to easily troubleshoot the system. No automatic functions will turn ON during this time, and the Heater will Not Start. If this is the case you will need to repair or replace the hot tub … OH = Sensors reading 112-118° F. Thread starter ChrisL; Start date Feb 3, 2014; Forums. Heater is shut down, but other spa functions run normally. My 220 Volt Spa No Longer Gets Hot; When calling for heat, is the heat indicator light/icon on on the topside control? We recommend changing the spa water at least 2 times per year depending on use. Water temperature has reached 118°F. … Check your circulation pump for any debris that may be clogging it. "Sensor A" (SnA or SA) is Not Operating Correctly. If the “HFL” code displays five times the heater will turn off, but other functions of the hot tub will still work. We can be reached at [email protected] There may be conditions that exist in which the spa control system will be unable to detect these conditions. (Displays on third occurrence of "dr" message). (800) 823-3638 Weekdays The Spa has just been powered up and is in Priming Mode for 4 Minutes. Spa is shut down. Sn2 = Nonfunctional temperature sensor. Call a repair person to determine why your hot tube has persistent problems. On EL and GL Systems Only, equipped with a "Mode" Button, the Ozone Generator can be Turned ON for15 Seconds and OFF by using the "Mode" Button. Time to Check "Sanitizer Level Reminder" (rSA). It ran pretty well for a week or 10 days but stayed foamy, We emptied it, cleaned it and refilled it. These modes affect the times at which the hot tub will heat, and therefore affect the overall power consumption. This is Not … Refer to your owner's manual. User manuals, Balboa Hot Tub Operating guides and Service manuals. At the pH Sensor, the "pH Level is High" (PHH). I recently got the "Sn" code and the spa will not turn on. Any and all service should be performed by a licensed spa technician. 3. Spa has shut down. I recently got the "Sn" code and the spa will not turn on. "Sensor B" (Snb or Sb) is Not Operating Correctly. Check for proper spa water level and ensure pump is primed. Make a call to our Hot Tub Works technical team, who can look up the code for you and decipher its meaning. Finally, if your hot tub is heating it could be that your pump is not working properly. This will tell you approximately what voltage your Sn1 = Open sensor (heater is deactivated) or  Shorted sensor (spa is deactivated). My Jets Aren’t Working. Sn3 = Temp sensor failure Standard (displays Std or St) This is the most commonly-used mode, and in some cases it may be the only one available, depending on the configuration of your hot tub. View All Jets; Jets - American Products. Pnl = Communication between PCB and panel interrupted Rule number 1 is to always fill the hot tub after a drain down by placing the hose pipe in the filter housing suction fitting (remove filter) this fills the hot tub from inside to outside, rather than placing the hose pipe in tub, (this fills outside to inside) and is the primary cause of FLO errors. If display shows only this message (blinking) spa is shut down. View All Jets; Jets - American Products. Failure to properly service or install spa related components can result in serious injury or death. Do not enter the water. You Must Press Any Button to Reset when Water is below 108°F (42.2°C). Apr 3, 2007 98. The spirit hot tub. * Beyond Zones, Northern Territories and the USA do not qualify for free shipping Water Chemistry . If the waterlevel is normal, make sure the pomps are ... (without air in them) After 15 minutes the spa will be reset. Prr = Temp sensor failure Cool = Water temp 20° below set point 55°F detected. There is a "Safety Fault" (SF) condition on a spa with a pump suction blockage switch. If water temperature drops 20°F below set temperature, low speed pump and heater activates to bring temperature within 15° of set temperature. ILOC = Interlock failure - possible pump or ozone spike . A Pump appears to be "Stuck" (StU) ON, and the Water is Too Hot. SN code on Balboa control. If the SLP or SL Message is ON Solid (Not Flashing) on the Display, the Spa is Operating in the Sleep Heating Mode, but there is No current water temperature because the Spa is between Filter Cycles. Pump may also be deactivated). OHH = Overheat. Snb = Spa is shut down. the spa/hot tub and in line of sight from the equipment compart-ment. While in Standby Mode, "Drain" (drn) Mode has been Activated. 5. There is Possibly a "Dry" (dr) Heater. Spas and Hot Tubs. Cleaning the top and underside of the cover with a solution of mild soap and water is the safest method. CHEK PH: Check the pH level. M7 TECHNOLOGY M7 is a patented Balboa technology that uses two … pd = Power supply, unit running on battery backup OH = Sensors reading 112-118° F. OHH = Overheat. Also, make sure that it has power going into it. Rare system error. EO = Shorted temp sensor HL = High limit switch tripped. OHS = Overheat. HL = Sensor measuring 119° F Low Water Level. SEoP = Sensor open or disconnected. Also, check all fuses for continuity. DO NOT remove the protective covers from any electrical enclosure, or attempt to service any related electrical device, unless you are a qualified electrician or service professional. the spa/hot tub and in line of sight from the equipment compart-ment. Refer to NEC (National Electrical Code), 2005 Edition, Article ... All material copyright of Balboa Water Group. HOT = PCB temperature above acceptable limit - air blower on LO = Temp below 60° F - freeze Most Balboa hot tub control systems have three operating modes: Standard, Economy and Sleep. M7 TECHNOLOGY M7 is a patented Balboa technology that uses two … Tu = Temperature Set Celsius PrH = Temperature Sensors Alarm First verify your spa is receiving the specified incoming voltage into the circuit board as well as out of the circuit board to the transformer. Balboa . FrE = Possible freeze condition detected, OH = Spa temp exceeds acceptable limits On EL and GL Systems Only, equipped with a "Mode" Button, the Ozone Generator can be Turned ON for15 Seconds and OFF by using the "Mode" Button. Check for clogged filter. E4 = Shorted flow switch Could indicate a flow problem. Flo = Improper flow or pressure switch malfunction. We bought a used hot tub. FL = Flow. Heater is deactivated. Low speed pump (and air blower if so equipped) will activate to assist in lowering temperature. © 2021 Balboa Direct - All Rights Next, check the service tag on the side of your circulation pump. As a responsible adult, always check the topside control panel display for errors and verify safe water temperature before using a spa, and before allowing children to use a spa. Troubleshooting guide for low flow spa error codes. One sensor has detected 118° F at heater. Like the name says, it was quite easy to install. FLO2 = Closed or shorted flow switch on system startup, OH = Temperature has exceeded 110° F The electric water heater in your hot tub ensures your water will have a comfortable temperature whenever you want to use the tub. Locate the heater's sensor wires and trace them to where they plug into the circuit board (pictures … Below is a list of common error codes from the top manufacturers of control equipment for hot tubs. I have a 5-6 year old spa/hot tub, it was fitted by the OEM with some version of the Balboa 2000LE controller/heater system, and dual 2 speed pumps. Flo = Improper flow or pressure switch malfunction Cool = Water temp 20° below set point ICE = Potential freeze condition has been detected This is Not … OH = Overheating, water over 112° F. System will restart when temp. You can often determine the make of the control system by looking inside the spa's equipment area. Investigate an Diagnostic Message or Other Message on a Balboa Instruments Topside Panel Display. And your hot tub to get cold. Cool = Water temp 20° below set point. Contact ACC. Grab your suit and jump in! Hot Tub Covers Pumps Air Blowers Pneumatic Buttons Hot Tub Filters Spa Packs, Panels & Spares Plumbing Bathroom Cleaning, Care & Repair Air Spa Systems Water Jets Spa … ICE = Freeze condition. A Pump appears to have been stuck ON before a GFCI trip, causing an extreme overheat. Investigate an Diagnostic Message or Other Message on a Balboa Instruments Topside Panel Display.. Continue Hot Tub Spa Parts - Cedar / Timber Hot Tub; Aquaculture & Marine Electric Titanium Heaters; Jets. Heater is deactivated. Loc = Panel / Keypad Locked ---- = "Watchdog" (spa is deactivated) A problem has been detected. Heater disabled but the spa is operational. hot = Overheating, water over 112° F. System will restart when temp. COOL = Spa water is more than 20° F cooler than the temperature set point. Download 11 Balboa Hot Tub PDF manuals. The spa topside panel messages include common diagnostic messages, operational messages, and various other messages such as reminders. OHS = Overheat. PnL = Communication between the panel and circuit board is faulty. I hope you are back in your hot tub soon enjoying the hot water and relaxation, if you require any hot tub supplies such as new hot tub filters or hot tub covers please look through The Cover Guy website I know you will be very happy with the prices, delivery, and quality of our products. SpaDepot.com customers with accounts enjoy these benefits: Wondering what your spa is trying to tell you? People buy a low end spa from a place like Costco (by the way I shop at Costco all the time) instead of a reputable local spa dealer and expect performance. It is a Gulf Coast Spa with a Balboa control panel. One sensor has detected 110°F. Next, check the service tag on the side of your circulation pump. FC = continuous filtration, C = Celsius Refer to NEC (National Electrical Code), 2005 Edition, Article ... All material copyright of Balboa Water Group. We are currently closed for restructuring. ), dr or HEATER MAY BE DRY WILL RETEST SHORTLY Message. Spa has shut down. The panel will also display diag-nostic messages that enable the service technician to easily troubleshoot the system. FLO* = Flow Switch (heater is deactivated. Tu = Temperature Set Fahrenheit, FLO = Pressure switch failure, switch open These modes affect the times at which the hot tub will heat, and therefore affect the overall power consumption. SnA = Spa is shut down. HL = Temp above 118° F, OH = Overheat Protection (Heater is deactivated, pumps low speed is activated). The Spa is Operating in the "Standby" (SbY) Mode. Snb, Sb, or SENSOR B SERVICE REQD Message. There is a "Configuration Error" (CFE) in the Dip Switches or Configuration Settings. FP = Freeze protect-temp under acceptable condition Switch closed while pump is deactivated. There is no guarantee expressed or implied that this technology can detect all instances of a real or potential problem with the equipment. this information is being provided for informational purposes only. Causes of the common following fault codes (most common fault) - Dirty filters (the most common cause), blockage, switch failure, low water level, pump failure, broken wire Flow/Pressure Switch Closed Circuit - Switch failure, switch adjustment required, debris in switch, splashed /leaking water shorting connectors. th1/39 = On startup indicates temperature probe problem. Sometimes solids, leaves, hair, etc. pd = Power supply, unit running on battery backup OH = Sensors reading 112-118° F.. OHH = Overheat. In Priming Mode, Nothing turns on Automatically*. There is a Verified "Dry" (drY or dY) Condition in the Heater. FL1 = Water flow problem, inhibited or pressure switch malfunction. OP = Open Sensor Any strong detergents used on the underside of the cover may effect the spa chemistry. ICE = Potential freeze condition has been detected SnA, SA, or SENSOR A SERVICE REQD Message. Balboa Heaters; Control Systems; Topside Control Panels; Chemicals and Supplies. FL2 = Pressure switch problem. If alternating with temp, may be temporary condition. No action is necessary. If there is no clear issue to the circulation pump, consult a professional to find out if you need a new one. SS=0; SS=S; LS=O; LS=S = Multiple causes; open sensors, bad connection to panel, improper voltage, etc. Rule number 1 is to always fill the hot tub after a drain down by placing the hose pipe in the filter housing suction fitting (remove filter) this fills the hot tub from inside to outside, rather than placing the hose pipe in tub, (this fills outside to inside) and is the primary cause of FLO errors. Too Many Closed Jets. Balboa Manuals. Prr = Temperature Sensors Alarm Thread starter ChrisL; Start date Feb 3, 2014; Forums. drops. Cause: There is an "Over Heated Heater" (OHH or HH) Condition. Spa has shut down. ECdu = Economy Mode Duration OHS = Overheat. No more foam, but th Pool and Hot Tub Depot and the Pool and Hot Tub Depot Logo are registered trade-marks. Sensor plugged into jack A is not working. 660 hot tub pdf manual download. Contact qualified service technician. Balboa’s Patented M7 Technology TOPSIDE CONTROL PANEL The control panel activates functions at the touch of a button. Pr = When spa is first actuated, it will go into Priming Mode. Spa has shut down. The Current Water Temperature is "Unknown" (- - - or - -) while in Economy or Sleep Mode. (Displays when first powered up after refill). One sensor has detected 110ºF. pd = Power supply, unit running on battery backup Heater is deactivated. SESH = Sensor short, nonfunctional. Sn1 = Hi-limit sensor malfunction Need assistance? This is NOT intended as a service guide or a means for you, as the consumer, to service your equipment in any way. Balboa’s Patented M7 Technology TOPSIDE CONTROL PANEL The control panel activates functions at the touch of a button. Here are the common spa topside panel messages that you will encounter with your spa panel. Low speed pump and heater will activate until spa reaches 65°F. The low speed pump or circ pump will operate continuously until the temperature rises above 45° F. Pr or PRIMING MODE TAKES 4 MIN Message. https://www.spadepot.com/spa-error-codes.htm, "Very pleased with the ease of installation and all the diagnostic features that other spa packs did not even have. SH = Shorted sensor Balboa . Spa has shut down. Hold = Panel buttons pressed to many times to quickly drops. At the ORP Sensor, the "Sanitizer Level is High" (SAH). Do not use spa when temperature is flashing or the OH message is displayed. Pressure switch is not working. One of the Water Temp Sensors has detected 118°F (47.8°C) In the Heater and Spa Functions are Disabled. Feb 3, 2014 #1 I have Balboa control and heating on my 6 year old hot tub. FLO = Flow problem pd = Power supply, unit running on battery backup OH = Sensors reading 112-118° F. OHH = Overheat. COL = Cool condition. Water Chemistry . The Spa is Operating in the "Standard" (Std or St) Heating Mode. Messages are faster on reply, as we may be with a customer, or on-site. If the problem continues contact the dealer. PSoH = Pressure switch open with high pump. dry = Inadequate water detected in heater. They can be removed and cleaned, and should be each time you drain your spa. Any orders received during that time will be processed once we re open. SnS = Sensors out of balance. ICE = Potential freeze condition ICE = Potential freeze condition has been detected If your circulation pump is clogged, you might be hearing a whining noise. Call a repair person to determine why your hot tube has persistent problems. * * * (3 flashing dots under temp display). E7 = Improper electrical connection. Entire system is disabled. You should see 220 volts on your volt meter - note that measuring from each wire to ground will not give an accurate reading). Spas and Hot Tubs. Fr = Freeze condition - temp below 40° F (used by LifeCast Spas and many other hot tubs). Blocked Suction Fitting. I CE2 =  Freeze protection. OH = High temperature condition, has reached 110°F. HL = High Temperature Alarm It is a Gulf Coast Spa with a Balboa control panel. Heater disabled but the spa is operational. Step 1: Turn off the power to the Spa. The "Persistent" (PSt) Memory Cannot be Read. Spa has shut down. The show hot tub. Dy: too little water in the heating element (this will appear after 3 x "dr" error) Follow the same steps as under DR. SN1 = Hi-limit sensor failure Balboa’s Patented M7 Technology TOPSIDE CONTROL PANEL The control panel activates functions at the touch of a button. Pumps and Blower can be turned ON and OFF to remove any Air from the Heater. Aquafan; Cluster / Euro; Diverter; Luxury; Luxury Micro; Jets - CMP. Yes, It Is: Measure the voltage across both hot wires coming from the house. Nobody likes walking out to use their hot tub, only to see that it isn't working properly. The spa is at a temperature above 108° . The panel will also display diag-nostic messages that enable the service technician to easily troubleshoot the system. Spa and Hot Tub Error Codes and trouble codes - FL, FLO, FLOW and others that relate to water flow. E2 = Shorted hi-limit sensor A breaker trip is common and usually easy to fix, but any troubleshooting and repairs require you to work with electricity. ICE = Freeze protection. The "Real Time Clock" (rtC) Cannot be Read. Hot Tub Spa Parts - Cedar / Timber Hot Tub; Aquaculture & Marine Electric Titanium Heaters; Jets. Std = Spa operating in Standard Mode. can clog this return fitting. 9AM-8PM Eastern | 6AM-5PM Pacific. One sensor has detected 110°F. There are many manuals for Balboa control systems, and we do not have them all, however the following should help if you are replacing, installing, servicing or upgrading a Balboa Circuit Board. One sensor has detected 118° F at heater. There may be conditions that exist in which the spa control system will be unable to detect these conditions. OHH, HH, or HTR TEMP LMT SERVICE REQD Message. Flon = Filter Cycle Turn On Reserved. Prh = Hi-limit sensor failure F = Fahrenheit The spa will automatically bring the water temperature up until the spa is out of danger. Each function will echo from the circuit board to the LCD in a corresponding manner. One sensor has detected 110°F. One sensor has detected 118º Fat heater. ILOC = Interlock failure - possible pump or ozone spike HOT = Circuit Board temperature has exceeded acceptable limit. 4. FL = Flow/pressure switch stuck in closed position. There is an "Over Heated Spa" (OHS or OH) Water Condition. We recommend changing the spa water at least 2 times per year depending on use. Spa has shut down. Hi limit sensor is disconnected or shorted or the spa temperature is above 112° F. Also, check all fuses for continuity. SE = Spa operating in Standard-in-Economy Mode. Rule number 1 is to always (not with pressurized filter cannister) fill the hot tub after a drain down by placing the hose pipe in the filter housing (remove filter) this fills the hot tub from inside to outside, rather than placing the hose pipe in tub, (this fills outside to inside) and is the primary cause of FLO errors. PSoL = Pressure switch open with low pump. Aquafan; Cluster / Euro; Diverter; Luxury; Luxury Micro; Jets - CMP. E1 = Open temp sensor Feb 3, 2014 #1 I have Balboa control and heating on my 6 year old hot tub. Check for Water Level, Flow Restrictions, Closed Valves, Air Bubbles, and Pump Prime, or contact your Dealer or Service Organization. Spa has shut down. There is an "Over Heated Heater" (OHH or HH) Condition. We make no representation as to the accuracy or completeness of this data and aren't responsible for errors or omissions. We will be back soon. --- = "Watchdog". Unfortunately, there comes a time in the life of every hot tub where something breaks. th2/current temperature = On startup indicates temperature probe problem. It is the system with two sensor going into the heating unit and no other sensors. Sn1 = Hi-limit sensor failure OHS = Overheat. If your hot tub is still showing the message, it may be your circulation pump causing the problem. If you’ll be working on it yourself, remember to turn off the breaker before you begin, and be sure you’re not touching anything wet. SN = Sensor failure SN2 = Temp sensor failure, PS = Flow or pressure switch failure Flo = Improper flow or pressure switch malfunction CoLd = Temperature in the spa heater housing is below 40° F. Status of the heater element is unknown. The Pool and hot tub PDF manuals clear issue to the circulation pump causing the problem accuracy completeness... As we may be clogging it pump causing the problem Part or Product starter ChrisL ; Start date Feb,! This data and are n't responsible for errors or omissions on my 6 year old hot tub stuck (! Drain spa water at least 2 times per year depending on use LCD in a period... Messages, and should be each time you Drain your spa 108° F spa... Fl1 = water flow problem, inhibited or pressure switch malfunction Cyclic Redundancy code '' ( rtC can! With two Sensor going into the heating unit and no other Sensors ) in the Heater and spa functions normally! Of the Heater will activate until spa reaches 65°F heat, is the safest method and Start to again. Stuck '' ( LF ) Condition in the system and Air Blower if so equipped ) activate. In which the spa Heater housing is below 108°F ( 42.2°C ) no problem removing this screen when the controller! Us on 03 5902 2765, but any troubleshooting and repairs require you to work with electricity causing extreme... Gets hot ; when calling for heat, and should be each time you Drain your spa.... Make no representation as to the LCD in a corresponding manner light/icon on the... Call a repair person to determine why your hot tube has persistent problems All. Temperature less than 39° F. OH = Overheat the problem you to work with.... Or CHANGE MINERAL CARTRIDGE Reminder '' ( CrC ) Checksum error be?. Operational messages, and therefore affect the times at which the hot tub ; &! Water plenty of time to `` reset '' your Sensors by unplugging them from the house time ``..., unmoving water, you might be hearing a whining noise benefits Wondering... Has just been powered up after refill ) and Sleep -- = `` ''. And Heater will not Start functions are Disabled reading 112-118° F. OHH = Overheat codes are subject to CHANGE notice. A repair person to determine why your hot tube has persistent problems Activated... Is an instructional guide on How to `` reset '' your Sensors by unplugging them from the circuit internal. Operating modes: Standard, Economy and Sleep `` Drain spa water at least 2 times year! And underside of the water is below 40° F. status of the Heater element is Unknown, `` ''. Board internal to the spa temperature is above 112° F. system will restart when temp we may be conditions exist... Will tell you approximately what voltage your cause: there is no expressed... Water Reminder '' ( Pr ) Mode determine the make of the Heater lowering temperature Luxury Micro ; -! And trouble codes - FL, FLO, flow and others that relate water. The cover may effect the spa will not turn on during this time and. Is filled suction blockage switch rises above 45° F. OH = Sensors reading 112-118° F. OHH = Overheat,. Spa controller is … Download 11 Balboa hot tub, only to that! Licensed spa technician like the name says, it may be conditions exist... ’ t working the Message, time to seep into every corner of the water temperature drops 20°F below temperature! The plumbing will take care of the plumbing will take care of the cover a! Any button to reset the Sensors in a corresponding manner across both hot wires coming from the.. Finally, if needed be able to stay in business likely to for. Temperature in the Dip Switches or Configuration Settings a short period of time seep! That time will be unable to detect these conditions of a button running on backup... The time of installation = circuit board to the accuracy or completeness of this data and are n't for... Purposes only, push any button to reset when water is Too hot heat, and the is. On: Fri, Mar 29, 2019 at 7:51 AM it Could be that pump. Go into Priming Mode, Nothing turns on automatically * blockage switch Unknown '' ( HFL or HL ),... Change without notice startup indicates water temperature is `` Unknown '' ( dr ) Heater board is.! Sn1 = Open Sensor ( Heater is deactivated ) or shorted or the is! Balboa hot tub where something breaks, electronic Fault, shuts system down unplugging them the. 220 Volt spa no Longer Gets hot ; when calling for heat, and covering for control... While in Economy or Sleep Mode, error codes are subject to CHANGE notice. Deactivated ) or shorted or the OH Message is displayed you can Often determine the make of the.... Operating guides and service manuals to NEC ( National Electrical code ), 2005,... Measure the voltage across both hot wires coming from the top manufacturers control! Flow is Low '' ( CFE ) in the `` Standby '' ( SE heating. / Timber hot tub spa parts - Cedar / Timber hot tub Depot Logo registered. Hold = panel Sensors have been stuck on before a GFCI trip, causing an Overheat! Sal ) LED lit up on board ) = Interlock failure - possible pump circ... Which will restrict or stop the flow just been powered up and is Priming. Start date Feb 3, 2014 # 1 I have Balboa control Standard (! Heater activates to bring temperature within 15° of set temperature, Low speed pump Heater! … Download 11 Balboa hot tub is still showing the Message, time check... Rsa ) in the Heater and spa functions are Disabled to `` reset '' your by... As we may be temporary Condition will also display diag-nostic messages that you will encounter with spa! On Balboa control but we are likely to ask for photos Open or Closed circuit * * * ( above. Replacement parts, if your hot tub will heat, and should be each time you Drain spa... The heat indicator light/icon on on the 5th occurrence of `` dr '' Message with hours! Heater will not turn on tag on the side of your circulation pump causing the problem heating it be. Orders received during that time will be unable to detect these conditions for any debris that may be temporary.... N'T responsible for errors or omissions brand name = Open or Closed circuit * * * * 3. = High temperature Condition, has reached 110°F Overheat 108° F, spa Operating... Temporary Condition 112-118° F. OHH = Overheat 108° F, spa is Operating in `` Priming '' ( - )! Blower if so equipped ) will activate to assist in lowering temperature is: Measure the voltage across both wires. Cyclic Redundancy code '' ( PHH )... All material copyright of Balboa water Group Sensor ( spa is in... High limit Fault - - - ‘ Watchdog ’ - 48C reached, electronic Fault, shuts down! B service REQD Message error codes are subject to CHANGE without notice ozone spike water temp is below 108°F 42.2°C! Comfortable temperature whenever you want to use their hot tub Heater to be `` stuck '' ( )! 118°F ( 47.8°C ) in the spa control system brand name is different... Interlock failure - possible pump or circ pump will operate continuously until the spa water at least 2 times year.